Significativa prolongación del tiempo de conservación de la córnea manteniendo sus tensiones y curva natural es

Authors

  • Roque Alejandro Maffrand Universidad Naccional de Córdoba
  • Sofía Parisi de Fabro Universidad Nacional de Córdoba

DOI:

https://doi.org/10.31053/1853.0605.v59.n2.38487

Keywords:

Cornea conservations, media, time tensions, curvaturetrame sistem transplant

Abstract

The success of cornea transplantationshas always been a concern of world researchers to identify risk factors from the proper surgical
techniques up to the severa] tissue storage procedures, such as the ones used in the new laboratories called eyes banks. However, the integral research works are still limited at present and they continue putting emphasis in the donor cornea storage that guarantee up tofor this tissue feasibility. This research had the aim to contributeto the improvement of the corneal tissue quality taking into account the maintenance of its na- tural curvature and tensions combining themwith sorne standard preservation solutions. This was achieved by rneans of a new mechanical system. Assays with rabbits were designed according to a sequential experimental groups design. In these ones, the study of the feasibility parameters behavior under different conservation media, related to the time, was splitted into four blocks. The first and second ones attended the cornea conservation in the short and intermediate-terms culture mediums as the ones at 40
C degree isolated cornea preservation and the usual ones such as the Me Carey Kaufman, Optisol and Likorol solutions used in the eyes banks. The third nne was designed for the surgical assays comino from the two named groups and the last one focused the time study of these parameters for a new conservation technique, developed as an alternative medium to keep the cornea tissue curvatures and tensions as well as its nutrition and hydration.
The results showed that tissue natural tensions maintenance is an significant factor in the conservation process, which involve the cornea feasibility for the its use in future transplantations. Since the new developed technique is very simple, this study is considered to be a significant contribution for the stoiage and biological material handling steps.

Downloads

Download data is not yet available.

Author Biographies

  • Roque Alejandro Maffrand, Universidad Naccional de Córdoba

    Facultad de Ciencias Médicas

  • Sofía Parisi de Fabro, Universidad Nacional de Córdoba

    Facultad de Ciencias Médicas

References

Adams, A. Ketamine in paediatric ophthalmic practice. Anaesthesia. 28: 212-213, 1973.

Arentsen, J. J. Cirugía del segmento anterior del ojo. 1° Ed. Bs. As. Editorial Médica Panamericana S.A. 1990. 384 pp.

Avery, G. S. Farmacología clínica y tera-péutica. Adis Press, Sydney y Nueva York. Barcelona. Salvat. 1983. 1316 pp.

Barraquer, J. y J. Rutllán. Atlas de microcirugía de la córnea. 1° Ed. Barcelona. Ed. Scriba, S.A. 1982. 398 pp.

Bourne, W. M. Endothelial ceil survival on transplanted human corneas preserved al 4°C in 2,5% chondroitin sulfate for one to 13 days. Am J Ophthalmol. 102(3): 382-386. 1986.

BRIGHTBILL, F. S. Cornealsurgery. Theory, technique and tissue. 2° Ed. St. Louis. Missouri. Mosby-Year book, Inc.1993. 763 pp.Capella, J. A.; Kaufman, H. E. y Robbins J. E. Preservation of viable corneal tissue. Arch. Ophtalmol. 74: 669-673. 1965.

Castroviejo, R. Atlas de queratectomías y queratoplastias. 1° Ed. Barcelona, Salvat Editores, S.A. 1964. 391 pp.

S. Ceraso, O.; Gimenez, J. C. y Hagman E. Anestesia balanceada con infusión continua I. V. de Ketamina. Comparación de la analgesia con morfina y procaína. Revista Argentina de Anestesia. 38. 2. 1980.

Costa Vila, J.; Canais, M. y Pita D. Eye bank and corneal transplant in 1944. Transplant Proc. 27(4): 2419-2425. 1995.

Delbosc, B. y X. Piquot. La conservation des cornées humaines. Convergence. Vol. 45-10F: 15-18. 1989.

Doughman, D. J. Cornea-Tissue storage. Mosby-Year book, Inc. St Louis, Missouri 63146. Krachmer J. H.; Mannis M. J. yE. J. Holland. 1997. Vol. 1, Chapter 39.976 pp.

Fernandez Meijide, R. Queratoplastias perforantes. Donante, receptor y adiestramiento quirúrgico. Arch Oftal de Bs. As. Vol LXVII: 81-116. 1992.

Filatov, V. P. Transpiantation of the cornea. Arch Ophtalmol. 13:321-347. 1935,

Griffith, F. N. The promise of international eye banking. mt Ophthalmol. 14 (3): 205- 210. 1990.

Harris, J. E. y NordquistL. T. The hydration of the cornea 1 The transport of wather from the cornea. A. M. Ophtalmol 40:100, 1995.

Kangas, T. A.; Edelhauser, H. F. y Twining S. S. Loss of stromal glycosaminoglycans during corneal edema. Invest Ophthalmol Vis Sci. 31: 1994-1998. 1990.

Kenneth, R K. The real corneal challenge: International eye banking. Ocular Surgery News. Vol. 8, N° 2: 6-7. 1997.

Lass S, J. H.; Bourne, W. M.; Musch, D. C., Sugar, A. y Col. A randomised, prospective, double-masked clinical trial of Optisol vs. DexSol corneal storage media. Arch Ophthalmol 110 (10): 1404-1408. 1992.

Lindstrom, R. L.; Skelnik, D. L. y Lass J. Optisol-a new 4°C corneal preservation solution. Invest Ophthalmol Vis Sci. 31: 475-477. 1990.

Mc Kinnon, J. R. y Walters G. D. Cadaver storage time: an important factor in donor cornea survival. Arch Ophthalmol. 94:217- 220. 1976.

Martonyi, C. L.; Bahn, C. F. y Meyer R. F. Clinical slit lamp biomicroscopy and photo slit lamp biomicrography. J Ophthalmic Photogr. 7(3): 77-80. 1984.

Nartey, 1. N.; Sherrard, E. S. y Steele A. D. M. Manipulative damage to the endothelium of infant and adult donor corneas. Br J Ophthalmol. 74 (5): 261-264. 1990.

Perkins, E. S.; David, W. H. yE. S. Sherrard E. S. Fundamentos científicos de la oftalmología. Córnea: estructura y transparencia. 1°Ed. Barcelona. Salvat Ed. S.A. 1981.435 pp.

Piquot, X.; Delbosc, B.; Herve, P. y Royer J. Presevation of human corneas in orgen culture; results of a feasibility clinical protocol. Buli Soc Ophthalmol Fr. 90: 429- 432. 1990.

Samar, M. E. y Avila R. E. Técnicas histológicas. Aspectos teórico-prácticos. 1° Ed. Córdoba, Arg. Ediciones Atica. 1991. 182 pp.

Seedor, J. A.; Stulting, D. R. y Epstein R. J. Survival of corneal grafts from donors supported by mechanical ventilation. Ophthalmology. 94: 101-108. 1987.

Sokal y Rolph. Biometría. 1983. Chapman & Hall. 756pp. Sulewski, M.; Orlin, S.; Rama, P.; Rama, G.; Tseng, S. H.; Lee, H.; Wang, C. C.;

Hung, G. Y.; Chen, M. Y. y M. S. Huang. Clinical study on efficacy of NaHCO3 free isotonic media (BFIM) for human cornea storage. Cornea. 16 (2): 255. 1997.

Torres de Cardena, A. M. y Col. Manual técnico y científico. Asociación Panamericana de Bancos de Ojos, (APABO). Extracto de Eye Bank Technical Manual. Eye Bank of America. 1988. 85 pp.

Waltman, S. R. y Kaufman H. E. In vivo studies of human corneal endothelial permeability. Am J Ophtalmol. 70: 45- 47.1970.

Downloads

Published

2002-08-19

Issue

Section

Original Papers

How to Cite

1.
Maffrand RA, Parisi de Fabro S. Significativa prolongación del tiempo de conservación de la córnea manteniendo sus tensiones y curva natural es. Rev Fac Cien Med Univ Nac Cordoba [Internet]. 2002 Aug. 19 [cited 2024 Nov. 13];57(2):163-80. Available from: https://revistas.unc.edu.ar/index.php/med/article/view/38487

Similar Articles

71-80 of 1973

You may also start an advanced similarity search for this article.