Punción aspiración ecoguiada con aguja fina de tiroides (PAEAFT) algoritmo dignóstico

Authors

  • María Irizar Universidad Nacional de Córdoba. Facultad de Ciencias Médicas
  • Luis Spitale Universidad Nacional de Córdoba. Facultad de Ciencias Médicas
  • Graciela Godoy Municipalidad de Córdoba
  • Carlos Canga Hospital Municipal de Urgencias

DOI:

https://doi.org/10.31053/1853.0605.v58.n1.37024

Keywords:

Fine needle aspiration (PAAF), - Fine needle aspiration of thyroid with ultrasonography guide (PAEAFT), specificity, sensibility, Tint 15, DIFF, QUIK, Cytologic diagnosis, Algorithm, thyroid nodulo

Abstract

Fine needle aspiration (PAAF) of thyroid it has demonstrated to he highly sensitive and specific to establish a diagnosis and to implement the corresponding Ireatment, these qualities are increased when the guide ecográfica is uscd: fine needie aspiration of
thyroid with ultrasonography guide (PAEAFT). 139 cases of PAEAFT are presented of whose material was carried out extended
conventional and thin acccrding to specific technique and they were colorcd with Haematoxylin and eosin (H & E) - Tint 15
(DIFF- QUIK) and Papanicolaou; analyzing their distribution for sex, age, topography, characteristic of nodules and cytologic
di agnoses.

The presumpti ve diagnoses corresponded to: Multinodular Goiter (21.58%) - Hashimotos thyroiditis (2.87%) -Follicular neoplasm: Under degrce (1-II): (57.57%), High degree (III): 2.15% - liürthle ccli tumors (2.87%) - Papilary carcinoma (4.32%). The prevalence corresponded to the female sex (93.5217c). The pursuit of the patients was caiTied out based on the proposed algorithm, modified
of that of Gharib, 1997.

Downloads

Download data is not yet available.

Author Biographies

María Irizar, Universidad Nacional de Córdoba. Facultad de Ciencias Médicas

II Cátedra de Patología

Luis Spitale, Universidad Nacional de Córdoba. Facultad de Ciencias Médicas

II Cátedra de Patología 

Graciela Godoy, Municipalidad de Córdoba

Departamento de Endocrinología . Dir. de Especialidades Médicas

Carlos Canga, Hospital Municipal de Urgencias

Departamento de Diagnóstico por Imágenes 

References

Akerman M., Tennvall J., Biórklund A., et al: Sensivity and Specificity of fine needle aspiration citology in the diagnosis of tumors of the thyroid gland. Acta Cytol 29:850-855, 1985.

Biopur, Vademecum y Manual de Técnicas. Rosario, 1998. Brander A, Viikinkoski P. Nickels J et al: Thyroid gland: US screening in a random

Adult population. Radiology. 181:683-687, 1991.

Burch H.B: Evaluation and management of the solid thyroid nodule. Endocrino] Metab Clin North Am. 24: 663-664, 1995

Canadian Task Force on the periodic health examination. Canadian Guide lo ClinicalPreventive flealth Car.Ottawa: Canada Communication Group,1994, p. 611.

Cochand - Priollet B, Guillausseau Pi, Chagnon S et al: The diagnostic value of Fine-Needle aspiration biopsy under ultrasonography in non functional thyroid nodules: a prospective study comparing cytologic and histologic findings. Am J Med. 97(2):I52-157, 1994.

Frost A. Sidawy M. Ferfelli Metal: Utility of thin laycr preparations in Thyroid Fine- Needie Aspiration - Cancer (Cancer Cytopathol.) 84(1): 17-25, 1998.

S. Farreras Valentí P, Rozman C. Medicina Interna. 13 Edición. Madrid. Mosby Doyma. 1995. Volumen II. p. 2053. Flynn MB, Tarter J, Lyons K et al: Frequency and experience with carcinoma of the thyroid at a private, a veterans administrations and a University Hospital. J Surg Oncol. 48:164-170, 1991.

García del Moral R. Laboratorio de Ana- tomía Patológica. l Edición. Madrid. McGraw-Hill. Interamericana de España, 1993. Rey. Fae. Cienc. Méd Córdoba 58 (1): 77-86 - 2001

Gharib H. Changung concepts in the diagnosis and management of thyroid nodules. Endocrinol Metab Clin North Am 1997; 26: 777-800.

Gordon DL, Gattuso P, Castelli M, et al: Effect of Fine-Needle aspiration biopsy on the histology of thyroid neoplasms. Acta Cytol. 37:651-654, 1993.

Guidelines of the Papanicolaou Society of Cytopathology for the examination of fine needle aspiration spec imenes from thyroid nodules: Modern Path.9:710, 1996. Hamburger JL: Consistency of sequential needle biopsy findings for thyroid nodules: management implications. Arch lntern Med. 147:97-99, 1987.

Hamburger JL, Ilusain M: Semiquantitati ve entena for Fine-Needie Biopsy Diagnoses: Reduced False-Negative Diagnosis. Diagn. Cytopathol. 4:14-17, 1988.

Jones AJ, Aitman TJ, Edmonds CJ et Al: Comparison of Fine-Needie Aspiration Cytology. Radiosotopic and Ultrasound Scanning in the management of Thyroid Nodules. Postgrad Med. J. 66:914-917, 1990.

Kini SR. Guides to Clinical Aspiration Biopsy: Thyroid. 2nd Edition. New York: Iguaku - Shoin, 1996.

Koss IG, Woyke S, Olszewsky W. Aspiration Biopsy: Cytologic 1 nterpretation and histologic basic. Chaptcr 1. 2"" Edition. New York: lguaku - Shoin, 1994.

Martin HE, Ellis EB: Biopsy by Needle puncture and aspiration. Ann Surg 62:169-181, 1930.

Martin HE, Ellis EB. Aspiration Biopsy. Surg. Gynecol Obstet. 59: 578-589. 1934.

Martin HE, Stwart FW. The Advantages an Limitations of Aspiration Biopsy. AJR 35:245-247,1936.

Mazzaferi EL: Management of a solitary thyroid nodule. N Engl. J Med. 328:553-559, 1993.

Orduna G, Pigni F, Casasús P, Grosso F. Punción Biopsia Aspirativa de tiroides bajo control ecográfico. Rey. Argent. Cirug. 73:70-73. 1997.

ürcll SR, Slerrett, Walters MNI, Whitaker D. The Thyroid gland in: Manual and Atlas of Fine-Needie aspiration. 2' Edition. Cytology. Churchill Livingstone, Longman Group UK Limited, 1992.

Paseyro P., Grosso O. El citograma tiroideo obtenido por punción. Sus aplicaciones prácticas. Medicina Panamericana, 6:13, 1956.

Piaggio Blanco, Paseyro P., Grosso O. El Citograma Tiroideo, su interes clínico. Arch. Uruguayo Med. Cir. y Esp. 32:81,1948.

Piromalli D, Martelli G, Del Pratto J, et al: The role of Fine-Needle aspiration in the diagnosis or thyroid nodules: analysis of 795 consecutive cases. J Surg Oncol. 50:247-250, 1992.

Rosai J. Ackerman's Surgical Pathology. 8' dition. New York. Mosby. 1996. Volume 1.p.493.

Schwartz S. Principios de cirugía. 6 Edición. México. Nueva Editorial Interamericana. 1995. Volumen II. p. 1655.

Smith - Purslow MJ, Kini SR: 1995 Cytopathology Laboratory Manual. Detroit, Henry Ford Hospital, 1995. .Silverberg S G, De Leilis RA, Frable WJ:

Pricipios and practice of surgical pathology and cytopathology. 3' Edition. New York. Churchill Livingstone Inc. 1997. Volume

p.2665.

Sóderstrdm N. Aspiration Biopsy Puncture of goitres for Aspiration Biopsy. Acta Med. Scand 144:237-244. 1952.

Sederstrüm N. Fine-Needle aspiration bíopsy. Stockolm. Amqvist & Wiksell,1966.

Stanley MW, Lowhagen T. Fine-Needle aspiration of palpable masses. Chapter 1. First Edition. Stoneham, MA: Butterworth- Heincmann, 1993.

The Papanicolaou Society of Cytopathology Task Force on Standards of Practice. Guidclines ot ihe Papanicolaou Society of

Cytopathology for [he examination of fine needle aspiration specimens from thyroid nodules. Diagn. Cytopathol.]5:84, 1996

Published

2001-11-30

How to Cite

1.
Irizar M, Spitale L, Godoy G, Canga C. Punción aspiración ecoguiada con aguja fina de tiroides (PAEAFT) algoritmo dignóstico . Rev Fac Cien Med Univ Nac Cordoba [Internet]. 2001 Nov. 30 [cited 2024 Jun. 29];58(1):77-86. Available from: https://revistas.unc.edu.ar/index.php/med/article/view/37024

Issue

Section

Original Papers