Distal radius fractures – Treatment with volar locking plates - Functional results according to fracture type

Authors

  • Juan Martin Patiño Hospital Militar Central
  • Alejandro Felix Rullan Corna Hospital Militar Central
  • Alejandro Michelini Hospital Militar Central
  • Ignacio Abdon Hospital Militar Central

DOI:

https://doi.org/10.31053/1853.0605.v77.n4.26516

Keywords:

distal radius, fractures, locking plates, outcomes, complications, osteosynthesis

Abstract

Background: The aim of this study is to determine if there are differences in functional results in patients presenting fractures of the distal radius treated with volar locking plates and, secondarily, to compare these results according to fracture type (AO).

Methods:  39 patients treated between January 2013 and December 2015 were evaluated. They were 19 women and 20 men, with an average of 60 years old and a range between 18 and 86 years old. The average follow up was of 46 months. We made radiographic postoperative measurements of the ulnar tilt angle of the radius, the volar tilt angle of the radius and styloid height. We evaluated residual pain with VAS (Analogue Visual Scale). The objective and subjective function were evaluated with the DASH inquiry (Disabilities of the Arm, Shoulder, and Hand) and Mayo wrist score.

Results: The mean flexion was of 51º, the extension was 55º, pronation was 80º, and supination was 75º. The mean ulnar tilt angle was 19, 66°, the mean volar tilt angle was  2.07°, and the mean styloid height was 8.97 mm. The average DASH was 14.38  and the average Mayo was of 78.58. There was no significant statistical correlation between the fracture complexity and the analyzed variables.

Conclusions: In this series, volar locking plates were a valid option for the resolution of unstable distal radius fractures in its different patterns and in a wide age range.

Downloads

Download data is not yet available.

Author Biography

Juan Martin Patiño, Hospital Militar Central

Jefe de servicio de cirugía de miembro superior. Hospital Militar Central. CABA. Argentina

References

1. Gouk C, Ng SK, Knight M, Bindra R, Thomas M. Long term outcomes of open reduction internal fixation versus external fixation of distal radius fractures: A meta-analysis. Orthop Rev (Pavia).2019 24;11(3):7809. doi: 10.4081/or.2019.7809
2. Yu X, Yu Y, Shao X, Bai Y, Zhou T. Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study. J Orthop Surg Res. 2019 27;14(1):271. doi: 10.1186/s13018-019-1309-4.
3. Mudgal CS, Jupiter JB. Plate and screw design in fractures of the hand and wrist. Clin Orthop Relat Res; 2006 445:68-80.
DOI: 10.1097/01.blo.0000205887.04200.21
4.Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma; 200418(8):488-493. PMID: 15475843
5.Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop; 2003 27(1):1-6.
DOI: 10.1007/s00264-002-0393-x
6.Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg; 2004 29(1):96-102.
PMID: 14751111
7.Rozental T, Blazar P.E.,Orrin I.F, BS, Chacko A.T.,Brandon B.S, Earp E. and. Day C.H. Functional Outcomes for Unstable Distal Radial Fractures Treated with Open Reduction and Internal Fixation or ClosedReduction and Percutaneous FixationA Prospective Randomized Trial J Bone Joint Surg Am. 2009
;91(8):1837-46. DOI: 10.2106/JBJS.H.01478
8. Souer JS, Lozano-Calderon SA, Ring D. ¨Predictors of wrist function and health status alter operative treatment of fractures of the distal radius¨. J Hand Surg; 2008 33(2):157-163. doi: 10.1016/j.jhsa.2007.10.003.
9. Wong KK,Chan KW, Kwok TK, Mak KH ¨Volar fixation of dorsally displaced distal radial fracture using locking compression plate¨. Journal Orthop Surg 2005;13(2):153-157. DOI: 10.1177/230949900501300208
10.Drobetz H, Bryant AL, Pokorny T, Spitaler R, Leixnering M, Jupiter JB. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg ; 2006 31(4):615-622. DOI: 10.1016/j.jhsa.2006.01.011
11.Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg ; 2000 5(2):103-112. PMID: 11301503
12.Orbay JL Volar plate fixation of distal radius fractures. Hand Clin. 2005 21(3):347-354. DOI: 10.1016/j.hcl.2005.02.003
13.Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report. J Hand Surg; 2002 27(2):205-215
14.Souer S.J, Ring D., Matschke S, Audige L, Hubert M. M, Jupiter J. “Comparison of Functional Outcome After Volar Plate Fixation With 2.4-mm Titanium Versus 3.5-mm Stainless-Steel Plate for Extra-Articular Fracture of Distal Radius. J Hand Surg; 2010 35(3):398–405. DOI: 10.1016/j.jhsa.2009.11.023
15.Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gab M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma; 2007 21(5): 316-322. DOI: 10.1097/BOT.0b013e318059b993

Downloads

Published

2020-12-01

How to Cite

1.
Patiño JM, Rullan Corna AF, Michelini A, Abdon I. Distal radius fractures – Treatment with volar locking plates - Functional results according to fracture type. Rev Fac Cien Med Univ Nac Cordoba [Internet]. 2020 Dec. 1 [cited 2024 Jul. 17];77(4):272-5. Available from: https://revistas.unc.edu.ar/index.php/med/article/view/26516

Issue

Section

Original Papers